Transformers for Special Application

22 Item(s)

GSSO 12 | 17,5 | 24 Indoor Support Current Transformer High Current CT

GSSO 10 | 20 High Current CTSupport Current Transformer for indoor application 100 A up to 4000 A with busbars. The current transformers are fully encapsulated in brown epoxy resin. The secondary Learn More

ASX 12 ... 24 Indoor Insulator-Type Bushing Current Transformers- and Insulator Bushing, Block-Type

ASX 12 ... 24 Indoor Cast resin Support insulator-type bushing current transformer. The current transformers are fully encapsulated in brown epoxy resin. The active part consists of one or more Learn More
New

KGBEA / KGBEI 24 | 36 | Metal encapsulated wideband combi-transformer for applications in the power quality field

KGBEA / KGBEI 24 |36 | Metal-clad indoor wideband combi-transformer with inductive single-pole voltage and current transformer section, touch-proof design. The indoor combi-transformers are fully Learn More
New

GSWS 24 Indoor Current Transformer with optional extended frequency range for PQ Measurement, (wideband transformer)

GSWS 24 Indoor Current Transformer with optional extended frequency range for PQ Measurement, (wideband transformer) frequency transfer characteristics up to 9 kHz, Calibratable (50 Hz)Block-Type; Learn More
New

GSES 12D / 24D Indoor Voltage Transformer with optional extended frequency range up to 9 kHz for PQ measurement, Narrow Design

GSES 12D / 24D with optional extended frequency range up to 9 kHz for PQ measurement indoor voltage transformer single-phase insulated, narrow design. The standard versions according to DIN 42600, Learn More

GSEFBC 15..25 Burst-proof Outdoor Railway Voltage Transformer

GSEFBC 15..25 The outdoor voltage transformer GSEFB is intended for use as an overhead voltage transformer on electrically operated railway vehicles (rolling stock). The insulation is made of outdoor Learn More

GSWFK 10...72,5 (12 ... 72,5kV) Outdoor Cascade Current Transformer

GSWFK 10...72,5 (12-72,5kV) Outdoor Cascade Current Transformer. The current transformer is designed for outdoor use. The cascade current transformer consists of the GSWF lower stage and the GSOF Learn More

GSE 45 Indoor Voltage Transformer for stationary railway application DIN 42600, Part 3, big type

GSE 45 | 52 |  45 Indoor Voltage Transformer, single pole, for stationary railway application DIN 42600, Part 3, big type.The indoor voltage transformers are fully encapsulated in brown epoxy Learn More

GSEFB 15..25 Outdoor Railway Voltage Transformer

GSEFB 15..25. The outdoor voltage transformer GSEFB is intended for use as an overhead voltage transformer on electrically operated railway vehicles (rolling stock). The insulation is made of outdoor Learn More

UGSSF(B) 704 / 710 Outdoor Current Transformer Split-core type, Railway Application

UGSSF(B) Outdoor Split-core type CT, Railway Application for outdoor use. Two core segments are cast with the secondary winding with brown epoxy resin. The core cutting surfaces are lapped to ensure Learn More

IRBT Indoor Generator Window Type Current Transformer

IRBT are single-conductor, window type current transformers, dry type, for Um 0.72 kV which are suitable for mounting on generator terminals; direct ratio up to 30,000 / 1 A (higher ratios on Learn More

LGSO 10...30 Indoor Window-Type Current Transformer Generator Transformer

LGSO 10...30 Indoor window-type current transformer direct rating up to 20.000/1A (higher rates on request). The transformers are single-wire current transformers for use in encapsulated generator Learn More

GSS 10 | 20 Indoor Support current transformer High Current CT

GSS 10 | 20 High Current CTSupport Current Transformer for indoor application 100 A up to 4000 A with busbars. The current transformers are fully encapsulated in brown epoxy resin. The secondary Learn More

GDW 12 | 24 Indoor Bushing Type Current Transformer

GDW 12 | 24 Indoor Bushing Type Current Transformer for Indoor application 5 A to 150 A, The current transformers are fully encapsulated in brown epoxy resin. The active part consists of one or more Learn More

GDS 10...36 24 Indoor Bushing Type Current Transformer Bar-Type

GDS 10 ... 36 Indoor application 150 A to 3000 A, The current transformers are fully encapsulated in brown epoxy resin. The active part consists of one or more toroidal cores with homogeneously Learn More

IGD 36 Indoor Bushing Type Current Transformer Bar-Type

IGD 36 Indoor Bushing Type Current Transformer Bar-Type Indoor application 100 A to 2000 A, The current transformers are fully encapsulated in brown epoxy resin. The active part consists of one or Learn More

GTDS(O) 10 | 20 | 30 Indoor Bushing Type Current Transformer

GTDS(O) 10 | 20 | 30 Indoor Bushing Type Current Transformer for Indoor application from 1000 A up to 10000 A, GTDS(O) bushing-type current transformers are used for large rated currents up to Learn More

GTDS(O)F 10 | 20 | 30 Outdoor Bushing Type Current Transformer

GTDS(O)F 10 | 20 | 30 Outdoor Bushing Type Current Transformer up to 10000 A, GTDS(O)F are used for large rated currents up to 10000 and above (on request) as a bushing-type with integrated current Learn More

GTDS(O)FI 10 | 20 | 30 Outdoor-Indoor Bushing Type Current Transformer

GTDS(O)FI 10 | 20 | 30 Outdoor-Indoor Bushing Type Current Transformer,fully insulated plug-in current transformers up to 10000 A, Outdoor bushing type current transformers GTDS(O)FI are used for Learn More

eA10A | 12 | Explosion-proof Support-Type Current transformer

eA10A Explosion-proof Support-Type Current transformer The Current Transformer eA10A is an explosion proof supporting type CT, designed for a maximum equipment voltage level of Um 11 kV and a rated Learn More

IRB Indoor Generator Window Type Current Transformer

IRB Window Type Current Transformers / Generator current Transformer for Indoor Application;The current transformers are foil insulated. Rated current from 500 A to 12.500 A. The transformers are Learn More

GSOFB Outdoor window type traction current transformer, Railway application

GSOFB Window type traction current transformer For outdoor use. The current transformers are fully encapsulated in brown epoxy resin. The secondary terminal box can be sealed. For measuring and Learn More

22 Item(s)