ZKSW 60 ...ZKSW 300, Indoor Interposing Current Transformer Series, Low Voltage 0,72 kV, are winding current transformers with galvanic separated primary and secondary windings. Both windings are mounted on a toroidal core. The active part is completely enclosed by two ultrasonically welded (ZKSW 300: snap-on) half-housings made of an impact-resistant polycarbonate plastic housing. The housing is viscoplastic, flame resistant and self-extinguishing.

Wound current transformers for indoor use, primary current 1 ... 20A, secondary current 1 or 5A with transparent terminal cover. For measuring (and protection) equipment.
Ask for further technical data and offers.
Please contact our Low Voltage Sales Department directly.
The contact details are:
Matthias Sickert, Tel.: +43 7243 / 522 85 21,
E-Mail: Matthias.Sickert@ritz-international.com,
Sebastian Stefan, Tel.: +43 72 43 / 522 85 58
E-Mail: Sebastian.Stefan@ritz-international.com
Hier finden Sie weitere Informationen und können das Produkt konfigurieren!
Die Auswahlfelder unten bieten Standardwerte, abweichende Werte bitte im Feld Sonderwünsche eintragen

Click here for more information and to configure the product !
The selection fields below offer default values, different values should be entered in the field Special Requests.


Details

ZKSW 60...ZKSW 300 Series, Indoor Interposing Current Transformer,
possible design options:

ZKSW 60, Size 1, Primary Current 1...20A, External dimensions (W/H/L): 60 / 73 / 30mm

ZKSW 60, Size 2, Primary Current 1...20A, External dimensions (W/H/L): 60 / 78 / 52mm

ZKSW 70, Primary Current 1...20A, External dimensions (W/H/L): 70 / 86 / 52mm

ZKSW 100, Primary Current 1...20A, External dimensions (W/H/L): 100 / 118 / 73mm

ZKSW 300, Primary Current 1...20A, External dimensions (W/H/L): 100 / 151 / 73 mm

Standard accessories: 2 foot fasteners and a transparent terminal cover.
Mounting in any position.

Application

1. At lower operating currents, when no direct measurement is desired (electrical isolation of the measuring circuit, keeping the operating voltage away, measuring instruments nominal current not equal to the operating current).
2. for connection to main transformer to the following purposes:
a) To reduce the conduction losses of long measuring lines: Reduce from e.g. 5 to 1 A at the installation location of the main transformer and, if necessary, increase from 1 to 5 A at the measurement location.
b) To protect sensitive equipment against overcurrents by means of a small overcurrent limiting factor with the most accurate selection of the actually required rated burden.
c) For matching the secondary current of the main transformer to the rated current of the equipment to be connected.

 

 

 

 


.    Bei kleineren Betriebsströmen, wenn keine direkte Messung erwünscht ist (galvanische Trennung des Meßkreises, Fernhalten der Betriebsspannung, Meßgeräte Nennstrom ungleich dem Betriebsstrom).
2.    Zum Nachschalten an Hauptwandler zu folgenden
Zwecken:
a) Zur Verringerung der Leitungsverluste bei langen Meßleitungen: Am Einbauort des Hauptwandlers untersetzen von z.B. 5 auf 1 A und bei Bedarf am Ort der Messung wieder heraufsetzen von 1 auf 5A
b) Zum Schutz empfindlicher Geräte gegen Überströme mittels kleinem Überstrom-Begrenzungsfaktor bei möglichst genauer Auswahl der tatsächlich erforderlichen Bemessungsbürde.
c) Zum Anpassen des Sekundärstromes des Hauptwandlers an den Nennstrom der anzuschließenden Geräte.

Additional Information

Place of Manufacture Made in Austria
Indoor Application Yes
Single Phase Yes
Ambient Temperature -5°C ... +40°C Yes
Mounting in any Position Yes
View File Datenblatt ZKSW 300 Size: (141.89 KB)
View File Data Sheet ZKSW 100 Size: (143.78 KB)
View File Data Sheet ZKSW 300 Size: (145.4 KB)
View File Beipackzettel ZKSW 60 ... 70 Size: (179.13 KB)
View File Datenblatt ZKSW 70 Size: (152.57 KB)
View File Datenblatt ZKSW 60 Gr. 2 Size: (156.11 KB)
View File Datenblatt ZKSW 60 Gr. 1 Size: (152.26 KB)
View File Datenblatt ZKSW 100 Size: (140.27 KB)
View File Data Sheet ZKSW 70 Size: (156.17 KB)

* Required Fields